 | CUBEFuse finger-safe fuse and fuse holder system
Finger-safe fuse and fuse holder system; dual-element, time-delay fuse;10 seconds minimum operating time at 500% rated amps. |
 | LPJ_SP Class J
Dual-element, time-delay fuse;
10 seconds (minimum) at 500% rated amps. Now available with optional permanent indication on select ratings |
 | LPN-RK_SP (250V) Class RK1
Current-limiting, dual-element, time-delay fuse; 10 seconds (minimum) at 500% rated amps (8 seconds for 0-30A sizes). Now available with optional permanent indication on select ratings |
 | LPS-RK_SP (600V) Class RK1
Current-limiting, dual-element, time-delay fuse; 10 seconds (minimum) at 500% rated amps (8 seconds for 0-30A sizes). |
 | LP-CC Class CC
Time-delay, current-limiting, rejection-type fuse 12 seconds (minimum)
at 200% rated amps. |
 | KRP-C_SP Class L
Time-delay fuse 4
seconds (minimum) at 500% rated amps. |
 | FRN-R (250V) Class RK5
Dual-element, time-delay fuse 10 seconds (minimum) at 500% rated amps. |
 | FRS-R (600V) Class RK5
Dual-element, time-delay fuse 10 seconds (minimum) at 500% rated amps. |
 | DFJ Class J
High speed, current-limiting fuse. The new Cooper Bussmann Drive Fuse will provide maximum protection for AC and DC drives and controllers and meet NEC branch circuit protection requirements. The Drive Fuse has the lowest I2t of any branch circuit fuse to protect power semiconductor devices that utilize diodes, GTOs, SCRs and SSRs. |
 | JKS Class J
Fast-acting, current-limiting fuse. |
 | KTN-R (250V) Class RK1
Fast-acting, current-limiting fuse. |
 | KTS-R (600V) Class RK1
Fast-acting, current-limiting fuse. |
 | KTK-R Class CC
Fast-acting, branch circuit, rejection-type fuse. |
 | KTU Class L
Fast-acting, bolt-mount fuse. |
 | KLU Class L
Time-delay, bolt-mount fuse - 5 seconds |
 | DLN-R (250V) Class RK5
Dual-element, time-delay fuse 10 seconds (minimum) at500% rated amps. |
 | DLS-R (600V) Class RK5
|
 | FNQ-R Class CC
Time-delay, branch circuit, rejection-type fuse. |
 | JJN Class T
Very fast-acting, current-limiting fuse. |
 | JJS Class T
Very fast-acting,
current-limiting fuse. |
 | SC Class G
Fast-acting (1?2-6A),
time-delay (7-60A) fuse. |
 | NON (250Vac/125Vdc) Class K5 & H
General purpose,
non-current-limiting fuses. |
 | NOS (600Vac) Class K5 & H
General purpose,
non-current-limiting fuses. |
 | W Series
Fast-acting plug fuse. |
 | SL Series
Time-delay, loaded link plug fuse. |
 | TL Series
Time-delay, loaded link plug fuse. |
 | S Series
Dual-element, time-delay plug fuse. |
 | T Series
Dual-element, time-delay plug fuse. |
 | Fustat Fuse Adapters
Adapters for using Type S and SL rejection fuses in Edison base fuse sockets. |